Connect with us

Buyers Guide old

Hematology Instruments

Product listing of various models available in the Indian market, with detailed capabilities and features, by brand

Brands

Models

Features

Agappe Diagnostics

BC 3000 plus (3-part hematology analyzer)

3-part hematology system; throughput: 60 samples per hour; technology: electrical resistance; parameter info: 19 parameters with 3 histograms; sample volume: 13 microliter in whole blood mode and 20 microliter in pre-diluted mode. Cell counting aperture size: 100 micron for WBC and 70 micron for RBC and PLT 10.4-inch color LCD display to view complete result with color histogram on the same screen. More than 35,000 result memory. Inbuilt key pad and external windows key board facility. Inbuilt thermal recorder and facility to connect external printer without any software, for printing the result

Mispa Count (3-part hematology analyzer)

Sample volume: 10 µl; throughput: 60 samples per hour; sample mode: open vial; type: double chamber; 3-part hematology with 20 parameters with 3 histograms. WBC, LY%, LY#, MID%, MID#, GRAN%, GRAN#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR touchscreen interface; 5 USB ports, RS 232 port, LAN port, SUBD-9 pins male, RJ45; aperture size: 80 micron for WBC and 50 micron for RBC and PLT

Mispa Count Plus (5-part hematology analyzer)

5-part differential analyzer with 3 histogram and scatter plot for WBC; 8.4-inch LCD touchscreen matching the eye contrast ratio; efficient system with throughput of 60 samples/hour; LED based flow cytometry; triple counting technology for accurate results; sturdy hardware with minimal maintenance & optimal workflow management; low operational cost and improved laboratory efficiency with cyanide free reagent; storage capacity of 35,000 results memory with scatter plot; sampling modes–whole blood (15.6 uL), pre-diluted (20 uL); aperture size of 80 micron for WBC & 50 micron for RBC and PLT; connectivity of 5 USB ports, RS 232, Ethernet–RJ45

AGD Biomedicals

PCE-210

Fully automatic blood cell counter with built-in self-monitoring system; touchscreen operation; 18 parameters with 3-part differential

Ark Diagnostics

Abacus 380

3-part fully automatic hematology analyzer with throughput of 80 tests/hr

Abacus 5

5-part automatic hematology analyzer with throughput of 60 tests/hr; 2 scattergrams using patented laser technology

Hematology controls

Controls for 3-part and 5-part hematology analyzers

Hematology reagents

All hematology reagents of Diatron hematology analyzers

Beacon Diagnostics

BC-10e

3-part differential hematology analyzer offering 20 parameters and 3 histograms, having throughput of 30 sample/hr, having better linearity for parameters. 50,000 patient result storage with histogram

Bonavera Count

3-part differential hematology analyzer with 60 samples throughput for 21 parameters and 3 histograms. 1 lakh result storage and built-in 4 QC program options

Beckman Coulter

DxH 900

It enables high-volume laboratory to achieve superb RBC, PLT and WBC differentials through near native-state cellular characterization. Industry-leading 93 percent first-pass yield ensures predictable costs and a faster break-even point. Streamlined processes help maximize staff time through the most reportable results per square meter in the industry, fewer slide reviews and high system reliability for greater uptime

DxH 520

A 5-part differential closed tube hematology analyzer, designed to help low-volume laboratory enhance patient care through increased productivity with reduced costs. The system delivers critical results the first time with accuracy, with as little as 375 µL tube fill-volume and an aspiration of only 17 µL—ideal for pediatric or difficult-draw samples. Technologists can experience safety without compromise with closed tube technology, providing optimal security against blood-borne pathogens. It also has one of the smallest footprints in its class, uses only three reagents, and features a robust patient data and QC management package

DxH 800

Put more science—not more staff—in high-volume hematology laboratory. With the DxH 800 hematology analyzer, can utilize accurate data about individual cell size, shape and structure to provide high-quality first-pass results. Go beyond mere cell counting to deliver results to clinicians and patients faster, with greater confidence

Early Sepsis Indicator (ESiD)

The Early Sepsis Indicator is an innovative test unique to DxH 900 hematology analyzers. This technology detects morphological changes in monocytes, cells of the innate immune system that provide a first line of defense against infections. Together with other laboratory findings and clinical information, the Early Sepsis Indicator provides clinicians with an alert as to the possibility of sepsis or risk of developing sepsis in adult patients entering the ED

Compact Diagnostics

IraDiff-3

3-part differential

IraDiff-5

5-part differential

CPC Diagnostics

Dynacount 5D

5-part innovative triangle laser count differential cells

Pentacyte

5-part hematology analyzer; 60 tests/hr throughput; time tested gold standard technology; fault diagnosis management; remote maintenance for quicker response

Xcyte Plus

3-part hematology analyzer; pediatric mode; 18 parameters and each parameter is measured in triplicate; low reagent consumption in standby mode; ready LIS & HMS connectivity

HiMedia

MBP008 – Alkaline Hemoglobin Electrophoresis
Kit (No Destaining Required)

intended for discrimination of hemoglobin variants using alkaline gel electrophoresis. This method uses a selective staining dye for distinguishing the haemoglobin types. It is a confirmatory tool for detection of sickle cell anemia.

MBP006 – Hi-Super Speed Sickle Kit (Solubility Test for detection of Hemoglobin ‘S’)

developed for screening of Sickle Cell Anemia, based on solubility difference between HbS and HbA

MBP001 – Alkaline Hemoglobin Electrophoresis Kit

intended for discrimination of hemoglobin variants using alkaline gel electrophoresis. It is a confirmatory tool for detection of sickle cell anemia.

MBP010 – Hi- Thal Kit

A turbidity based Screening kit for Thalassemia

Horiba Medical

ABX Micros 60

Open tube/closed tube; fast analysis–higher productivity; low sample volume required; low reagent consumption; low maintenance

Pentra XLR

Reticulocyte parameters in addition to CBC and differential parameters; high throughput of 80 samples/hr; large capacity automatic rack loading (up to100 tubes)/CDR facility

Yumizen H550/H500 Series

Compact 6-differential analyzer with an auto sampling system, safe sample management, continuous loading, automatic sample mixing, and positive identification of samples

Mindray

CAL 8000

Fully automated cellular line system with throughput of up to 800 samples/hr, with integrated slide stainer & LabXpert software integrating all the information at a single interface. The hematology system is equipped with SF CUBE technology, providing 37 reportable parameters along with IMG & NRBC along with each sample, with additional RET count with IPF & 48 research parameters

BC-6800/6800Plus

5-part differential analyzer; SF cube technology; autoloader can load up to 100 sample tubes; optical platelet counting, with IPF as reportable parameter; advanced research parameters like microcytic and macrocytic count for RBCs; up to 200 tests per hour

BC-6000/6200

5-part differential analyzer, unique SF cube cell analysis technology (laser scatter + fluorescence + 3D analysis) NRBC result in every CBC+DIFF count, with additional RET count, whole blood and body UID analysis; up to 110 tests per hour

Sysmex 

XN-1000

First step toward hematology automation with 100 samples/hour analysis speed. Only instrument capable of analyzing platelets with 3 different technologies and human progenitor cell counting

XN-1500

Robust and compact solution for hematology counter integrated slide maker and stainer with onboard decision rules

XN-3000

Upgradable to digital imaging system. True walkaway system

XN-9000

XN-series automated hematology analyzer

XN-350

XN-L series is the latest compact fully automated 6-part differential hematology analyzer having throughput up to 70 samples/hr

XN-450

Designed to meet laboratory needs by providing enhanced clinical values up to 70
samples/hr

XN-550

6-part differential hematology analyzer utilizing fluorescent flow cytometry method with automated IG count for better diagnosis and patient monitoring. Hourly throughput of up to 70 samples

XP-300

A compact fully automated three-part differential hematology analyzer that performs reliable analysis of 20 parameters (both in WB and PD mode) and displays result with 3 histograms on a color touchscreen

pocH-100i

A compact 3-part differential hematology analyzer, designed for near patient testing and low sample volume laboratories

SP-10/SP-50

New generation slide maker and stainer (with a throughput of 120 & 75) for every smear preparation need

TS-10

XN-9000 upgradability with tube sorter. Capable of sorting at least 400 tubes/hour

DI-60

Digital cell image analyzer for blood and body fluid analysis. Can be integrated with XN-1500/XN-3000/XN-9000

Transasia Bio-Medicals

H 360

3-part differential hematology analyzer reporting 22 parameters including PLCC & PLCR; requires low sample volume (9 µL) for all age groups; loaded with built-in printer and barcode scanner; customizable report formats and flexible printing options; unique ADDM & RIMS; large data storage capacity of 50,000 reports with graphs; large 10.4-inch LD touchscreen monitor

H 560

5-part differential hematology analyzer reporting 32 parameters including PLCC, PLCR, nRBC, ALY, LIC (% and #); based on tri-angle laser flow cytometry for accurate and precise reporting; requires low sample volume (15 µl) for all age groups; available with barcode scanner and external printer; unique ADDM & RIMS; large data storage capacity of 100,000 reports with graphs; large 10.4-inch LCD touchscreen monitor

Elite 580

5-part differential hematology analyzer reporting 29 parameters with unique 3D WBC differential scattergram; based on tri-angle laser flow cytometry for accurate and precise reporting; requires low sample volume (20 µl) for all age groups; throughput of 80 tests/ hr; Integrated auto-sample mixer and barcode reader; unique ADDM & RIMS; large data storage capacity of 100,000 reports with graphs

Trivitron Healthcare

Cellenium 380

3-part fully automated double chamber hematology analyzer; 22 hematology parameters including 3-part differential; throughput of 80 tests/hr; environment friendly diluents and cleaner reagents and cyanide-free lyse

Cellenium 5D Retic

5-part differential hematology analyzer with throughput of 60 tests/hr; 34 parameters with 2 histograms for RBC & PLT and 2 WBC scatter grams

Reagents

Wide range of reliable and accurate hematology reagents; compatible with all types of semi-automated and fully-automated analyzers

Others: BioSystems Diagnostics, DSS Imagetech, ELITechGroup, Iris Healthcare Technologies, Kee Diagnostics, Medsource Ozone Biomedicals, Meril Diagnostics, Nectar Lifesciences, Nihon Kohden, Rapid Diagnostics, Suresh Enterprise, Tulip Diagnostics, and Vanguard Diagnostics.

Product Showcase

Dynacount 5D CPC Diagnostics

India is one of the fastest growing markets in IVD, as diagnostics testing is gaining very high prominence with clinicians in making important decisions to treat the patients. The hematology testing, which is no exception, has seen tremendous growth in the last few years.

What is interesting is that in the last two years the 5-part analyzers market has grown faster than the 3-part. In fact market data suggests that among all analyzers sold this year, approximately 50 percent was 5-part. This trend is very prominent in tier I and tier II cities. One of the main reasons for this is the competitive pricing of new models of 5-part cell counters and lower cost per test. Also the new 5-parts are really compact and sometimes come with touch screens thereby removing the need for an external desktop to program and feed patient data in the instrument. Clinician behavior is also fueling this change as they find it useful to test a 5-part differential instead of requesting a 3-part and then a 5-part again for further diagnosis.

This transformation is also accelerated by the COVID pandemic as the need for cell counting is important in treating the patients, lots of new labs directly go for a 5-part instead of starting with a 3-part and then upgrading in a few years. Another catalyst to this transformation is that a lot of labs that have been using a 3-part are upgrading very quickly to 5-part, a 5-part Instrument also allows the user to perform in 3-part mode that gives the flexibility to perform both types of tests on the same instrument .

With so many brands in the market competing for the customer’s attention, how do buyers judge and decide on which product is suitable for their lab? Well for starters always ask for a demonstration to validate metrics like cost per test and consumable consumption. Minimum features one should expect are:

  • In-built PC with LCD touchscreen;
  • Large capacity of result storage with histograms on the instrument;
  • Connectivity to LIS;
  • Basophil count on the laser scattering technology; and
  • After sales support during the whole life of the product.

In addition to impedance to measure RBC and PLT, a 5-part instrument employs the advanced principle of flow cytometry to differentiate WBC into their five major sub-populations—neutrophils, lymphocytes, monocytes, eosinophils, and basophils—based on cell size and complexity (granularity). This opens up a whole gamut of diseases and conditions that can be diagnosed over a much simpler 3-part cell counter.

Labs, however, need to be careful as some 5-part analyzers are not truly 5-part, as in, they do not give all the 5 differentials using lasers. Some of the differentials are still given using impedance or optical absorbance. Customers need to be clear on this before they freeze on a model. Also, total cost per test must include the cost of the clean cycle. Clean cycles vary per model and are essential to prevent carryover of results. Some instruments have a single clean cycle at the end of the day. Some have clean cycles at the end of every test. How the instrument works is essential in comparing the cost per test of various providers.

CPC Diagnostics has been offering solutions for automation for more than 20 years, through new-generation instruments suitable for high, mid, and small laboratories, with excellent after-sales support and remote-diagnostics facilities.

 

 

 

Copyright © 2024 Medical Buyer

error: Content is protected !!