Connect with us

Life Sciences 2022

Miscellaneous

Shimadzu Analytical
GCMS-QP2020 NX
Featuring enhanced instrument functionality, analysis software, databases, and a sample introduction system; Helps maximize the capabilities of the laboratory

GCMS-QP2010 SE
Column flow up to 4 mL/min and variety of column selection; Enables direct sample injection and easy expandability without any changes to the GC

CLAM-2030
Fully Automated Sample Preparation Module for LCMS® Minimizes human error. Increases laboratory efficiency by allowing user to directly place the sample in system

LCMS-8050
Offers high-sensitivity quantitation delivered at high speeds; Rapid multi-component analysis; Simultaneous qualitative and quantitative analyses; Uf scanning at 30,000 u/sec, Uf switching – positive/negative Ionization switching in 5 msec, UF-MRM at 555 ch/sec

ICPMS-2030
Provides superior sensitivity. At the same time, thanks to the adoption of its proprietary mini-torch unit and provision of an Eco mode, the quantity of argon gas needed for analyses has been greatly reduced to the industry’s lowest levels. As a result, low running costs are assured. The Development Assistant function of the software automatically sets the optimal analysis conditions for quantitative analysis. Then, after measurements are complete, the Diagnosis Assistant function automatically checks the validity of the necessary data. While reducing the burden on the user, the efficiency of analyses is enhanced and the reliability of the data can be increased. It complies with FDA 21 CFR Part 11

MALDI-8020

  • 200 Hz solid-state laser, 355 nm
  • Load-lock chamber for fast sample introduction
  • UV laser-based source cleaning (patented)
  • Small footprint/benchtop design
  • Quiet operation (<55 dB)

MALDI-8030

  • Dual mode (positive/negative ion) MALDI-TOF
  • 200 Hz solid-state laser, 355 nm
  • Load-lock chamber for fast sample introduction
  • UV laser-based source cleaning (patented)
  • Flexibility
  • Small footprint/benchtop design
  • Quiet operation (<55 dB)

MALDImini-1
Utilizing its unique experience developing Digital Ion Traps, Shimadzu has introduced the smallest MALDI-based instrument available: the MALDImini-1. The size of a piece of paper and the recipient of a Red Dot Design Award, the MALDImini-1 enables users to perform advanced mass spectrometry experiments, including comprehensive structural analysis, in spaces never before possible.

AXIMA Assurance
Linear MALDI-TOF mass spectrometry for reliable mass information.

An affordable, robust option for all laboratories requiring routine manual or automated analysis of a wide variety of sample classes.

High sensitivity system using a variable repetition rate 50 Hz N2 laser and a variety of target formats to meet all sample throughput requirements.

AXIMA Confidence
Powerful MALDI-TOF performance for reliable mass information and MS/MS derived structural detail.

Linear mode allows the interrogation of high molecular weight samples, whilst reflectron mode, incorporating the patented curved-field reflectron (CFR), provides the high resolution and mass accuracy necessary for successful proteomics and life science experiments.

High sensitivity system using a variable repetition rate 50 Hz N2 laser and a variety of target formats to meet all sample throughput requirements.

An affordable robust option for all laboratories requiring routine manual or automated analysis of a wide variety of sample classes.

Excellent sensitivity is achieved using near-axis laser irradiation and advanced ion optics for enhanced ion transmission.

MS/MS may be easily performed using a seamless approach – ions of interest can be isolated using a precursor ion selection device, incorporated as standard, and data-rich fragment ion spectra quickly and simply acquired.The newly improved curved field reflectron design augments the low mass fragment region providing useful additional information.

AXIMA Performance
From high energy MS/MS of proteomics and other biological and organic samples to uncompromised analysis of high mass intact proteins

True high energy MS/MS – CID with a laboratory frame collision energy of 20keV

Optimal precursor ion selection resolution using revolutionary gating technology

Outstanding sensitivity – uncompromised design, to ensure no MS/MS signal is discarded

MALDI-7090
The MALDI-7090 is targeted for proteomics and tissue imaging. It combines Shimadzu’s extensive MALDI TOF-TOF mass spectrometry expertise with novel patented technology to provide ultimate performance in identification and structural characterization of biomolecules.

Market leading MS/MS resolution

Proprietary solid state UV laser technology

Ultra Fast acquisition speed in MS and MS/MS

Integrated 10 plate loader

Newly designed MALDI Solutions™ software

AA-6880
Enhanced Flame Analysis

World-Class High-Sensitivity Furnace

Evolving System Configuration

Advanced Safety Technolgy

AA-7000
The AA-7000 series of Atomic Absorption Spectrophotometers features high-sensitivity analysis, flexible system configuration, and a compact footprint for user-friendly operation. In addition, the AA-7000 systems are the first AAs to employ a vibration sensor as standard. The AA-7000 series ensures efficient and comfortable operation in your laboratory

AA-7800
The Shimadzu Atomic Absorption Spectrophotometer AA -7800 Series is versatile enough for a variety of analytical applications (Any Application), safe and easy to use even for beginners (Any User), and offers continuous analysis using autosamplers and remote data analysis via network connections to increase the flexibility of the analysis operator’s work style (Any Location).

Copyright © 2024 Medical Buyer

error: Content is protected !!